GENERAL INFORMATION
A-ETDRS (Automated ETDRS)
- Utilized in multiple PMA studies in both IDE and IND studies
- Peer reviewed and published by Southern College of Optometry, August 2015, submitted and approved for publication in “Optomtery & Visual Performance”
- Can be used at Distance, Intermediate and Near testing distances and is fully customizable to accommodate non-standard calibration distances
- Data can be automatically uploaded to any EDC or reading center from anywhere in the world (requires internet connection)
- Tablet controlled for error free operation
- Lifetime Technical Support - 24 Hour Technical Support for International Investigator Sites
FEATURES
- Quickly and accurately measure visual acuity while eliminating technician bias and erroneous results
- Choose Sloan letters (10), British Standard Institution letters (12), Euro-wide Letter Set, Landalt Rings or LEA Symbols
- Each presentation is randomized thereby eliminating the memorization effect and is consistent and repeatable
- System calibration set in meters at virtually any distance, and is adjustable and precise to within 1 cm
- The system is calibrated for both distance-to-subject and pixels-per inch so that optotypes precisely follow ANSI Z80.21-2020 and ISO 8596:2017 in regard to size, spacing between optotypes, and spacing between lines
- Background luminance is carefully calibrated to 85 cd/m2 for standardized ANSI and ISO testing or any other background luminance from 80 to 320 cd/m2, or as required for a study
- System luminance can be automatically calibrated and ambient room conditions measured with the optional integrated luminance photometer
- ETDRS results indicate ETDRS numerical score, visual acuity level and log value
- Test results can be exported to any media file in any format for statistical analysis or automatically uploaded to any EDC or reading center
USE & OPERATION
- The system is controlled by a high-resolution tablet via a standard Bluetooth connection utilizing our CustomLink® technology
- The testing mechanism interfaces seamlessly with CTS (Clinical Trial Suite) to allow the technician to follow the protocol as determined by the sponsor
- A descending ETDRS logMAR chart is presented using the Sloan letter set or any other available letter set
- The subject responds with the smallest line where all five letters can be correctly identified and the technician simply enters the line number and presses “Submit”
- The chart then randomizes, setting the selected line to the top line and a pointer is shown at the next smaller line
- The subject is then asked to read this line and the number of correct letters is input; the pointer moves to the next line
- The test continues until the subject is no longer able to correctly indentify any letters within a line
- When the test is complete the results are reported in the standard ETDRS Letter Score, Visual Acuity equivalent and logMAR equivalent
HARDWARE OPTIONS
M&S Smart System® 20/20 USA All-in-One Computer
- High-resolution 22” display
- Designed and developed by M&S in Niles, IL
- Manufactured in the USA (applies to SS-2020-USA)
- Industrial grade componentry ensures longer product lifespan compared to computers built for the retail/consumer market
- USA technical support based in-house at M&S in Niles, IL
- One-year warranty
Touch-Screen Laptop
- High-resolution 13” display
- Lightweight and portable
- USA technical support based in-house at M&S in Niles, IL
- One-year warranty